For dental light-cured 3D printed products, common dimensional issues such as overly tight or loose assembly of dental crowns, occlusal splints, surgical guides, and removable restoration models can be addressed by adjusting the three major slicing parameters: AB tolerance compensation, XY-axis contour compensation, and exposure parameters, which can basically solve such problems. Select and adjust AB tolerance compensation or XY contour compensation according to the model type; if the error is excessively large (e. g., ≥0.05mm), calibrate the exposure time first and gradually correct the fitting tolerance.
If the guide rings of surgical guides, dental restoration models, implants are assembled too loose or too tight, the AB tolerance compensation can be adjusted.
I. AB Tolerance Compensation Adjustment Independent Fine-tuning of Inner and Outer Diameters of Hollow Parts
Function of Parameters
AB tolerance compensation can independently split the dimensions of the outer contour and inner contour, and individually adjust the outer diameter and inner diameter to specifically solve the matching failure caused by the asynchronous internal and external dimensions of hollow workpieces such as crowns and sleeves. Corresponding to the tolerance compensation function in the menu bar of the slicing software, it is a core parameter for the precise dimension correction of dental hollow parts.
Adjustment Rules
Value A inner diameter compensation used to control the size of the inner bore
• Positive value: The inner contour converges inward, the inner diameter decreases, the inner wall thickens, and the inner bore becomes tighter
• Negative value: the inner contour expands outward, resulting in a larger inner diameter, thinner inner wall, and looser inner bore
B value outer diameter compensation controls the size of the outer contour
• Positive value: the outer contour expands outward → the outer diameter of the dental crown increases, and the outer ring assembly becomes tighter
• Negative value: inward contraction of the outer contour → smaller outer diameter of the dental crown, looser assembly of the outer ring
Practical Recommendations
• First, confirm whether the problem lies in the inner hole fit or the outer ring fit.
• Adjust the corresponding A value or B value separately, and a fine adjustment of 0.005 to 0.01 mm is recommended each time.
• If adjustments are required for both the internal and external parts, you can modify A and B simultaneously, but please note to set positive and negative values accordingly.
Note: If the AB compensation value is excessively large, for example, greater than 0.15mm, it will affect the support; it is recommended to use a medium support or a thick support.
If the orthodontic dental model shows an excessively large or small fitting degree upon scanning, the X-Y axis contour compensation can be adjusted.
II. XY Axis Profile Compensation Adjustment Uniform Correction for Overall Profile
Function of Parameters
XY contour compensation is used to uniformly scale all contours of the model, to compensate for the contour dimension deviation caused by resin curing contraction and ultraviolet edge diffusion, optimize the overall insertion and fitting performance of the part, and it acts on all inner and outer edges of the model.
Adjustment Rules
• Set the compensation to a positive value (+): the entire contour of the model will expand outward, with both the outer diameter and inner diameter increasing synchronously, which improves the problem of overall loose insertion and extraction.
• Set the compensation to a negative value (-): The entire contour of the model will be retracted inward, with both the outer diameter and inner diameter reduced synchronously, which can improve the problem of excessively tight insertion and extraction.
Practical Recommendations
• Single fine adjustment range: 0.01~0.03%, large-scale adjustment is not recommended.
• After testing to confirm the dimensions or fit, proceed with secondary optimization.
Applicable scenarios: The overall internal and external dimensions of the part are simultaneously too large/too small, or there is an abnormal tightness in the overall assembly;
Not applicable scenarios: When the dimensional deviations of the inner and outer rings are inconsistent (e. g., the outer ring is tight while the inner ring is loose), switch to AB tolerance compensation.
If the fitting error of the guide ring hole or the implant is greater than 0.1 mm, the exposure time can be recalibrated.
III. Exposure Parameter Check Priority Check Item Error greater than 0.1mm
Resin undergoes photopolymerization and curing when irradiated by ultraviolet light, and the exposure duration directly determines the curing expansion of the resin, which is a core factor affecting the overall basic dimensions of the part:
Verification Method: First, print a 10×10×10 mm cube uniformly according to the platform size, measure the dimensional deviation of the X and Y axes, and conduct the actual model test only after the cube's dimensions meet the requirements.
Excessively long exposure time measured size > design size
• Cause: Excessive exposure time leads to over-curing of the resin, and excessive cross-linking of the resin at the edges results in swelling.
• Adjustment: Gradually reduce the single-layer exposure time, make a fine adjustment of 0.1s each time, and re-measure the dimensions until the assembly tightness meets the requirements.
Insufficient exposure time measured size < designed size
• Cause: Insufficient exposure time leads to incomplete curing of the resin, resulting in excessive contraction after molding and shrinkage of the overall dimensions.
• Adjustment: Gradually increase the single-layer exposure time, with a recommended fine adjustment of 0.1-0.2s each time, to supplement the curing degree so as to counteract natural contraction.
Note: Exposure is a global parameter. After modification, the inner and outer diameters of the entire plate model will change synchronously, and the dimensions of the inner and outer rings cannot be distinguished separately. When the dimensions of the inner and outer contours are inconsistent, exposure correction cannot be relied on, and it is necessary to enable AB tolerance compensation.